Humidity Resistance Testing in Chennai

Humidity Resistance Testing in Chennai

Humidity Resistance Testing in Chennai

A small river named Duden flows by their place and supplies it with the necessary regelialia. It is a paradise

Introduction

Humidity Resistance Testing in Chennai

.


🎯 The Challenge: Unexplained Failures Post-Distribution

A Chennai-based packaging supplier started facing complaints:

  • Food sachets puffed up prematurely

  • Films discolored under storage

  • Seal integrity failed within 30 days in humid retail shelves

The material passed visual QC and tensile tests. But one thing hadn’t been tested: humidity resistance.


🔍 Diagnosis: Moisture Barrier Weakness

The team collaborated with a local NABL-accredited testing lab. Over a 3-week test program, they ran:

  • MVTR testing (ASTM F1249): Showed >20 g/m²/day, too high for intended shelf life

  • Accelerated aging under 85% RH, 40°C: Revealed delamination and seal creep

  • ASTM D2126: Confirmed dimensional instability due to absorbed moisture


🧪 The Fix: Better Testing, Better Material Design

Armed with data, the team switched to:

  • A multilayer film with EVOH barrier

  • Moisture scavengers in the inner sealant layer

  • Updated specs with MVTR < 3 g/m²/day

They also made humidity resistance testing part of their QA plan, including:

Months

Since the change:
✔ No product complaints from humid zones
✔ Improved export compliance (EU, ASEAN)
✔ Shorter troubleshooting cycles thanks to archived humidity data


📘 Key Lessons for Manufacturers

  • Humidity testing is preventive—not reactive

  • Test to the climate of your customer, not just your factory

  • Use local Chennai labs—they understand the city’s real environmental stresses

  • Involve humidity tests early in R&D and packaging design


💬 Final Word

In Chennai’s climate, it’s not a question of if humidity will affect your material—it’s when.

Are your plastics and rubbers truly tropical-ready? The right test today can save your brand tomorrow.


Let me know if you’d like to turn this story into a downloadable case study PDF or a LinkedIn post series!

 
 
You
Humidity Resistance Testing in Chennai

Conclusion

 

FAQ

What prompted the need for humidity testing in the case study?

The manufacturer faced post-distribution failures—seal failures, film puffing, and discoloration—linked to high humidity exposure.

What specific tests helped identify the root cause?

MVTR testing (ASTM F1249), accelerated aging at 85% RH/40°C, and ASTM D2126 (dimensional stability) revealed poor moisture resistance.

What materials were affected?

Flexible packaging films used for food sachets were impacted. The root issue was excessive moisture vapor transmission and seal layer weakness.
Tags: No tags